Monday, 28 April 2014

Tunturi Treadmill Error E7 | Roughening of the potentiometer´s shaft | Remove E7 Error

Due to uncertainty concerning the service actions to the treadmills in case of the E7 error code,
please find below instructions how to remove the E7 error. 

The E7 error code indicates that the values the lift motor potentiometer sends are not within the
preset limits. The potentiometers’ I/O value can be checked in the console’s service menu by first
pressing the SELECT button, then the SPEED DOWN button and by holding both down for two
seconds. Thereafter the console lights will flash indicating that the engineering mode has been
entered. Press the ENTER button five times to check the value of the potentiometer; it is shown in
the TIME window. Compare it to the minimum and maximum reference values in table 1 (*2
nd page).

The potentiometer value is also displayed on the console when the E7 error code appears. Exit the
engineering mode by the same key sequence as in entering. 
If the readout from the potentiometer is 1 the software is not picking any signal from the
potentiometer

Possible reasons:
Lift motor rotation sensor (potentiometer) cable disconnected
Lift motor rotation sensor has poor internal contact and is thus providing incorrect values
The second connection cable between the console and the lower board is disconnected 
The potentiometer has lost its calibration and rotated to minimum 
If the readout from the potentiometer has lost its calibration setting and it differs from reference
values, adjust potentiometer (Figure 1) to obtain correct value. 

Figure 1 Lift motor potentiometer adjustment and how it affects on readout value
If the potentiometer has lost its position it can be lifted up by removing the two attachment screws.
Turn the potentiometer shaft to obtain the correct setting and place the potentiometer back to the lift
motor.  
To ensure that the potentiometer maintains the correct calibration setting, use pliers to press some
ridges to the potentiometers shaft. This will ensure the adhesiveness by increasing the rougness of
the shaft before inserting it back to its counterpart (see below).

Treadmill Lift motor potentiometer value table 
The values in the  * Table 1 are reference information for troubleshooting only. Resistance is measured from black and white wires (see picture in 3rd page).  

Figure 2 The lift motor potentiometer resistance at 0 % inclination (measurement between the
black and white wires)    
Contact us for any information or buy replacement treadmill motors on our shop.

Dynamix Cross Trainer repair | SEG-1682 Console's IC Chip Replacement



Contact us for information, visit our eshop for stationary bikes and crosstrainers replacement parts  

Follow the above steps to repair controller of SEG crosstrainer

1        Remove the screws from the console cover
2        Follow the photo to find the correct IC chip
3        Use the screwdriver or hand to slightly remove the IC chip
4        When finish the IC chip's remove process, the result would similar to the photo on the left-hand side
5        Before assemble the new IC chip, make sure the direction of IC chip need to be accurate. One side of the connection area has a gap                                   
6    Slightly press the IC chips down for finishing the IC chip's replacement




York treadmill E1 trouble shooting

York treadmill E1 flowchart
Contact us for any information and buy on our eShop York treadmill parts.

Astar 101 | AsTek TD700 | AsTek TD800 | AsTek TD1600 | AsTek TD1800 | AsTek TD1400 | AsTek TD350 | AsTek TD550


Astek treadmill controllers have been used on many different treadmills manufacturers,if you need replacement, buy on our eShop treadmill controllers or contact us for any information

Torque setup

Please turn clockwise or counterclockwise for half scale every time to get higher or less torque.

Alatech treadmill controller 6690 error codes | Alatech treadmill controller connections

Error messages on Alatech treadmill controllers

8.1『Treadmill error E01』:SPEED SIGNAL IS MISSING
8.2『Treadmill error E02』:OVER VOLTAGE PROTECTION
8.3『Treadmill error E03』:OVER CURRENT IS MUCH MORE 5 SECONDS
8.4『Treadmill error E04』:MOTOR PROBLEMS
8.5『Treadmill error E06』:COMMUNICATION FAILURE
8.6『Treadmill error E09』:INCLINE CHECKING PROBLEMS
8.6『Treadmill error E0P』:SPEED CHECKING PROBLEMS
8.7『Treadmill error E0C』:SHORT-CIRCUIT PROTECTION
8.8『Treadmill error E0E』: EEPROM  IS DAMAGED

Alatech treadmill controller connections
Available treadmill controllers? Buy it here:
  1. Alatech
  1. Treadmill controller 220 to 240 VAC input (Europe / Asia / Australia)
  2. Treadmill controllers 110-120 VAC input (North America)  
  3. Other fitness equipment parts

Saturday, 19 April 2014

PMDC Motor for treadmill

PMDC stands for Permanent Magnet Direct Current Motor. This is the most common type of motor used on home use treadmills.

Buy on our eshop convenient Permanent Magnet Direct Current Motor for treadmills

Sunday, 6 April 2014

Running belt | how to replace and how much walking belts cost

1. Motor Hood removal and replacement

2. End Cap and Side Rail removal and replacement

3. Rear Roller removal
4. Front Roller removal
Before beginning, mark the position of the Belt Tension Bolt. You can do this by counting the number of threads on the tension bolt or noting the location relative to the round hole on the side of the mounting bracket.
 5. Deck removal

Replacement Steps: A. Use a silicon lubricating spray on the inside of the belt before installation. B. Place the new belt inside the treadmill frame as shown in the picture to the right.
Don't forget to tension and center the walking belt.

Buy high quality, brand new running belts from 65£ 
Buy european quality treadmill running decks from 49£