Saturday 15 February 2014

Treadmill Engineering mode (Endex Controllers)

1. Engineering Mode Procedure:
i.     When the console is at standby status, press “ENTER” and “SPEED  ︿”  to enter the Engineering Mode.
ii.    The Dot Matrix Window shows VER; the Alpha Numeric Window shows model and version; the Incline Window shows year; the Time Window shows date and the Speed Window shows wheel(roller)  size.
iii.   Press “ENTER” button to show version of motor “LD” or “ISP”.
iv.   Press “ENTER” button to enter the Metric/English system setting.(see the instruction in Clause 2)
v.    Press “ENTER” button and the Dot Matrix Window shows “INPUT WHEEL SIZE”, enter the wheel size setting(Metric system: 400~900,±1, Default: 635; English system:1.60~3.50, ±0.01, Default: 2.50)
vi.   Press “ENTER” and the Dot Matrix Window shows “INPUT MIN SPEED”, enter the min. speed setting(Metric system: 0.8~1.5, ±1, Default 0.8; English system: 0.5~1.2, ±0.1, Default 0.5)
vii.  Press “ENTER” and the Dot Matrix Window shows “INPUT MAX SPEED”, enter the max. speed setting(Metric system: 10.0~20.0, ±0.1, Default: 10; English system: 6.0~12.4, ±0.1, Default: 6.0)
viii.  Press “ENTER” button to show the total distance of storage currently.
ix.   Press “ENTER” button to show the total time of storage currently(Hours).
x.    Press “ENTER” button to return to the standby status.
Note: Press “ENTER” and “INCLINE  ﹀” to initiate the system.

2. Metric/English Setting Procedure
i.     When the console is at standby status, press “ENTER” and “SPEED  ﹀”  to enter the Metric/English system setting.
ii.    The console shows “KMTYPE = KM”. Press “︿” or “﹀” buttons to select Metric/English system(KM stands for Metric system ; ML stands for English system)