Friday 11 May 2018

Motor integrity test

Remove the faston connectors from the M + and M- motor board. Set the multimeter / voltmeter to 200 VDC. Connect a test lead to the red cable (M +) and one to the black cable (M-). Turn the flywheel with your hands.
Normal result:
the faster the motor is turning, the higher the voltage produced. If no voltage is seen and the cables are connected correctly, the motor must be replaced. The DC motor, in fact, acts like a dynamo